WLD-M200 Water Leak Conventional Module in Chennai
WLD-M200
The WLD-M200 series of water leak modules are designed with high speed microcontroller. The module is 230V AC operated and DIN rail mountable. Existing water leak detection systems available in the market use a 12V /24V DC supply for sensing leaks. When DC excitation is used in the sensing cables they form electrolysis during the presence of water and forms corrosion around the sensing cables. This reduces the sensitivity over a period of time to virtually zero. However WLDM200 module uses AC as a sensing voltage, it does not corrode or degrade due to the alternating nature of the current and hence maintains the sensitivity of the sensing cables throughout its lifetime.
The module communicates with the master CS8ZWLD panel. In the case of sensor cable/communication cable becomes faulty, the master panel generates a cable open fault. The module has built in power to supply a 12V hooter connected to it & also has a volt free contact for field level hardware integration.
Features
- LED Status of leak status
- VFC output
- Audible buzzer
- Input Voltage : 230V AC
- Frequency : 50Hz
- Zones : 1
- Audio : Piezo Buzzer
- Visual : LED for Alarm
- Relay Contacts : 1 Amps @ 24V DC
- Fault relay to panel
Water leakage can cause serious damage in commercial buildings, industrial facilities, data centers, and electrical environments if it is not detected at an early stage. Even a minor leak can gradually affect infrastructure, equipment, and operational safety. As WLD-M200 Water Leak Conventional Module manufacturers in Chennai, we provide advanced leak detection modules designed to monitor water presence accurately and provide immediate alerts when leakage occurs.
The WLD-M200 module belongs to the WLD-Mxxx series of water leak detection modules developed using a high-speed microcontroller for reliable monitoring and fast response. The module operates on 230V AC power and is designed for DIN rail mounting, allowing easy installation within control panels and monitoring systems. Its compact and efficient design makes it suitable for integration with modern building monitoring systems.
Advanced Leak Detection Technology
Most of the conventional water leak detection systems found in the market operate on 12V or 24 V DC to detect leaks. In a sensing cable with DC voltage, water can also cause electrolysis, and hence corrosion will take place around the sensing cable conductors. With time, this corrosion leads to a decrease in the sensitivity of the cable, and the overall detection performance is compromised.
The WLD-M200 module removes this problem by accomplishing AC sensing voltage rather than DC. Since alternating current always reverses direction, it inhibits the formation of electrolysis and corrosion on the sensing cables.
Benefits of AC sensing technology
- Removes corrosion in sensing cables.
- The sensitivity of cables is maintained longer.
- Guarantees stability in leak detection.
- Minimizes repair and spare parts.
The design will make the leak detection system reliable during the period of its operation.
Seamless Integration with Monitoring Systems
The WLD-M200 water leak module links directly to the CS8ZWLD master panel, enabling the centralized monitoring of leak detection systems. This communication would also allow managers at the facility to monitor the conditions of the leak effectively and act in time whenever there is a problem.
If the sensor cable or communication cable becomes faulty, the master panel automatically generates a cable open fault alert, ensuring that the system continues to operate reliably.
- Connection to the master monitoring panel of CS8ZWLD.
- Sensor and communication cable fault detection.
- Simple interconnection with building security systems.
- Predictable signal transmission to detect leakages.
These characteristics are used to ensure the efficiency of the leak detection system in critical environments.
Alarm and Notification System
The WLD-M200 module is simple to use, has visual and auditory alarming options that instantly indicate to the user if there is a water leakage. LED indicators are easy to see and update the technicians on the status of a leak within seconds.
The module also has an in-built piezo buzzer that creates an audible alarm during instances of leakage. It also supports a 12V hooter power supply to be built in, allowing external alarms to be attached in case of heavier alerts in bigger facilities.
- LED indicators for leak status monitoring
- Audible buzzer for instant alarm notification
- Support for external 12V hooter connection
- Volt Free Contact output for external integration
These notification features make sure that the maintenance teams are able to respond to the occurrences of leakage promptly.
Key Features of WLD-M200 Module
The WLD-M200 Water Leak Conventional Module also has a number of new features that increase its monitoring power and the reliability of the system.
Key features include:
- Status display on leak detection.
- Volt Free Contact (VFC) output
- Built-in audible buzzer
- Input voltage: 230V AC
- Operating frequency: 50 Hz
- Monitoring capability: 1 zone
- Visual LED alarm indication
- Relay contacts: 1 Amp @ 24V DC
Choose Us today
As experienced WLD-M200 Water Leak Conventional Module manufacturers in Chennai, we focus on providing high-quality leak detection modules that help protect buildings, infrastructure, and critical equipment. Our solutions are designed to offer reliable monitoring, easy installation, and long-term operational efficiency.
By using advanced AC sensing technology and intelligent monitoring features, the WLD-M200 module ensures accurate water leak detection and improved protection for modern facilities. Prevent operational downtime with real-time Water Leakage Detectors from Kambar Technologies.